babylonware.com

Home > Error In > Error In Polygon Intersection Ram

Error In Polygon Intersection Ram

Contents

Consider the geometry pictured below. I have seen this error in several of the models (I review quite a number of models in our office). Under normal circumstances, zero-length beams cannot be modeled, but they can be imported from DXF or Revit, or they can sometimes result from modifications to the grids after the beams have Modeler - Data Check When a polygon error occurs while running the data check, the modeler will terminate. check over here

asked 4 years ago viewed 461 times active 4 years ago 19 votes · comment · stats Related 6How to intersect lines and polygons in R?9Rgeos drops associated values when intersecting Issue with ray polygon intersection algorithm Backups are made immediately prior to each and every scan providing you with the choice of undoing any changes with just one click. Work Around:   Analyze using the In-Core Direct Sparse Solver. Work Around: Install the 32-bit version.

Internal Error In Advanced Node List Ram

Resolution: This issuewas resolved in v14.06.01. At this point the backup file should be used, see below. Note that this can affect integration with RAM Concept. Below are several common modeling configurations that cause problems for the program but are not caught by Data Check.

  • Try remodeling the slab edge using the whole perimeter command.
  • Until recently, the only way to avoid tooling defects causing air traps, voids, shrinkage and the like was to employ a time-consuming and tedious physical prototyping process.
  • Once you do this, you should see the data from PondMaker in the pond and pond outlet elements in the model.
  • Next, highlight “2) Storage Estimate.” This step uses the calculated post-development inflow hydrograph and the target peak flow found in Step 1 to estimate the storage volume for the pond.
  • If you choose “Scenario,” you can then choose the target scenario, which will be the pre-development scenario.
  • RE: RAM Steel "Fatal Error: No Beam Loop Intersection Found" JMorrison (Structural) 13 Apr 07 15:21 I know I've seen that one, trying to bring the ol' memory online here...Does the
  • Work Around:   None Resolution:   This issue was resolved in v14.06.01.   CAN/CSA S16-09 Minimum Composite Problem:   The S16-09 Specification permits a percent composite as low as 40% when

Occasionally, errors or warnings occur during this process. If that transpires, what you are going to need to have depends in your Personal computer. Small gaps in the perimeter framing can also cause problems.   Forcing a "Reframe" In some cases the beam design module can open and not require a rebuilding of the framing Ram Frame Unstable Structure Detected For more information on the contents of the Ramis.ini file, refer to the  RAM Defaults Guide [TN] .  Are RAM Structural System models backwards compatible?

Cancel Red Flag SubmittedThank you for helping keep Eng-Tips Forums free from inappropriate posts.The Eng-Tips staff will check this out and take appropriate action. The .usr file is normally deleted when the model is closed, but if the program terminated irregularly, the file might persist. Resolution:   This issue was resolved in v14.06.01.   Column and Footing DXF Problems:   When changing the Color/Layer options in the Footing Schedule tab, a crash occurs. If the Error In Polygon Intersection Ram error message isn't going to give every one of the data you need, make use of the subsequent assets to find out more: Try

Since creating or modifying a symbol closes the open project page, be sure to enable the "Restart wizard after symbol save" checkbox on the "Save Symbol" step if the intent is to No Deck Assignment Found Inside Slab Boundary The second problem is a corrupt or partial model file. Instructions for downloading installation files can be found here: Accessing SELECT Services Online RAM Frame In-Core Direct Solver Problem: Analysis time with the In-Core Direct Solver (selected in RAM Frame - If a polygon error occurs while the framing tables are being built, the user can identify the beam number and coordinates together with the floor type where the program stopped processing

Ram Illegal Framing Configuration Detected On Beam

Note: PondMaker is available in older releases of PondPack as well, such as PondPack V10. The designed pond and outlet structure will not be exported to your model unless you do this step. Internal Error In Advanced Node List Ram It can be found at: http://www.microsoft.com/downloads/details.aspx?FamilyId=85E0C3CE-3FA1-453A-8CE9-AF6CA20946C3&displaylang=en Something is wrong with my model file, is there an automatic backup? Internal Error In Putnodeinlist RAM SS Common Framing Table Errors [TN] Product(s): RAM Structural System Version(s): 13.00.00.00 or later Environment: N/A Area: Analysis Original Author: Bentley Technical Support Group Framing

See Also Product TechNotes and FAQs Haestad Methods Product Tech Notes And FAQs External Links Water and Wastewater Forum Bentley Technical Support KnowledgeBase Bentley LEARN Server Comments or Corrections? Desktop 3D printers need not be used for making parts themselves, but as a secondary process for producing tools. These values are quite different. Work Around :  None. Ram Ss Instability Found At Rigid Diaphragm

Spaces are allowed as are references to mapped drives, but for the reasons mentioned above, a local drive should be used. For more information, see the TechNotes on Scenario Management and Active Topology Selection. Here's Why Members Love Eng-Tips Forums: Talk To Other Members Notification Of Responses To Questions Favorite Forums One Click Access Keyword Search Of All Posts, And More... This can be done with gArea(gIntersection(small area, large area))/gArea(small area) Which I execute inside a foreach loop that returns a 2200 by 70 matrix of weights.

You will also need to have the storm data set up for the scenario you are modeling. Illegal Framing Configuration Or Missing Slab Edge Detected For A Wall If these beams are modeled parallel to the deck span, they will take no tributary load from decking. Once the pond data is entered, select the “Compute Step 3” button.

In order to isolate the problem area the user should systematically remove stories from the story data until it works, then go back and examine the loads or decks on the

The objects can be aligned to one another, or to a grid intersection or any user provided coordinate. In Windows Explorer, navigate to the working directory (C:\Program Data\Bentley\Engineering\RAM Structural System\Data\Working). In the Options tab of this table, you can set up the tolerances you wish to use during the PondMaker process. Illegal Framing Configuration Or Missing Slab Edge Detected For A Beam Work Around: When designing per S16-09, input the correct value of ns where nt is input.

This comes from surfing, downloading packages, and any sort of usual computer system use. The alternative would be to allow PondMaker to select the pond dimensions based on a set of parameters. Efficient Typing on a Gameboy FizzBuzz Implementation in Java Polish tights for ladies Define functions for multiple shells Mountaineering with a 6-year-old kid in winter How can there be 0.5 atoms The polygon error may be followed by a second error message saying, “SetLineEq() passed two identical points at 0.00 0.00”.

That will delete the existing polygons and should resolve the meshing issue. To finalize, click the Export to Scenario button. Simply delete the .usr file and the .rss file can then be opened. Resolution:   This issue has been resolved in v14.06.01.

Column and Footing DXF Problems: When changing the Color/Layer options in the Footing Schedule tab, a crash occurs. Click your 'Start' Button. 2. If you have sloping framing, the column offsets must be very precise. Be aware that the "Use text style" and "Use text height" options for each text style in Project Options Standards Text Settings will, if enabled, override the text properties given to text in

summary(g) Object of class SpatialPolygonsDataFrame Coordinates: min max x 32.45725 32.82836 y -12.58917 -10.92426 Is projected: FALSE proj4string : [+proj=longlat +datum=WGS84 +no_defs +ellps=WGS84 +towgs84=0,0,0] Data attributes ... Adding the short beam on Gird B between the two concrete columns completes the loop with beams 40, 39 and 41. PondMaker is a feature that streamlines detention pond design by guiding you step-by-step through this process. Another advantage to these registry cleaners is that repaired registry errors will strengthen the speed and performance of one's procedure drastically.

In this case, it is necessary to delete and re-apply that surface load in a different area. If you try to convert a model from an older version and the custom tables used with the original file are not present on the PC converting the file you can Cancel -Structural Analysis Wiki +Limcon +Microstran +MStower +RAM Concept +RAM Connection +RAM Elements +RAM SBeam V5.0 -RAM Structural System +Known Issues in Ram Structural System +RAM Concrete RAM Modeler +RAM Steel Work Around: Analyze using the In-Core Direct Sparse Solver.

Thanks for the info.” Your Name Your Email Comment Ram Structural Error In Polygon Intersection There are many things that ram structural error in polygon intersection your PC might have, RCAll that is necessary for the triumph of evil is that good men do nothing.Edmund Burkewww.tbastructures.com RE: RAM Steel "Fatal Error: No Beam Loop Intersection Found" prsconsultant (Structural) 30 May 07 If you try to convert a model from an older version and the custom tables used with the original file are not present on the PC converting the file you can Consult your Help documentation in PondPack V10 for steps to use PondMaker in that version.   Before using PondMaker:   PondMaker will help design ponds and outlet structures, but you must

Beam or Column Design - Framing Tables When any design module is initiated, the program starts by “Building the Framing Tables”. Next, highlight “3) Pond Dimensions.” This step allows you to enter the pond dimensions manually or have PondMaker develop the dimensions for you. Open Windows Explorer and find the .zip file with "Orig v14.5" at the end of the file name that is automatically created during the conversion process.

© Copyright 2017 babylonware.com. All rights reserved.